HotLoop Gateway
An industrial automation gateway in one static Go binary.
Category: HotLoop
Current release: HotLoop 4.21.1, built for amd64 and arm64. It carries 4.21.0's changes, and the release notes list every version.
HotLoop Gateway polls PLCs and servers in their own protocols, keeps every reading and its quality in a historian, raises alarms, runs automations against all of it, and hands the plant to agents over the Model Context Protocol. A site runs one app, the Gateway and its database, instead of a historian, an alarm server and a rules engine glued together.
What it does
- Speaks OPC UA (subscriptions, not polling), Modbus TCP and RTU, MQTT with Sparkplug B as a full primary host application, EtherNet/IP, S7comm, MTConnect and HTTP/REST.
- Historises to TimescaleDB, with a deadband per tag, and every reading carries good, uncertain or bad quality. A bad reading is unknown, never zero.
- Evaluates ISA-18.2 alarms and pages them out to ntfy, Gotify, Discord, a webhook or email.
- Runs automations, scripts, recipes and blueprints, and keeps a logbook of every state change, write, alarm and config change on one timeline.
- Exposes the plant over MCP so agents can read it, and drive it where you allow.
Writing to equipment is the part to take seriously, and HotLoop is built that way. Writes ship switched off, every tag is read-only until somebody arms it, a value outside its range is refused instead of clamped, and every attempt is audited before it touches the wire.
When to use it
Use HotLoop Gateway when a site needs to read its equipment, keep history, alarm on it and act on it, and you'd rather run one thing than four. It's the top of the HotLoop lineup, with fleet management, multi-site roll-ups and scheduled reports. For a small box at the edge that only needs to read and forward, use the HotLoop Edge Relay, which feeds a Gateway over Sparkplug B.
What changed in 4.21
- OPC UA clients can sign in with a certificate. An admin attaches a client's
public certificate to a HotLoop user in Settings, and a client that holds the
private key signs in as that user, with that user's permissions and no password.
Revoking a certificate ends its session within seconds, and every certificate
sign-in and refusal is in the logbook. It stays off until the OPC UA server's
ALLOW_X509setting is on. - Passwords of 65 to 72 bytes sign in over OPC UA. They always worked in the web interface.
- The deprecated
Basic128Rsa15andBasic256security policies are off by default, on new installs and upgrades. A legacy client that speaks nothing newer connects again when that option is turned on. Check your OPC UA clients before you upgrade.
The HotLoop family
HotLoop is eight products for the plant floor: four that grow with a site (IoT, Edge, Gateway, and Edge Relay), Flow for wiring, Cascade for workflows, HotLoop for CODESYS, and Transmitter. The App Store lists seven of them, one per product:
- HotLoop Gateway is this page: the full historian, alarm server, automation engine and MCP surface, with fleet management and reports.
- HotLoop Edge is HotLoop IoT plus what a box at the machine needs: an OPC UA server so a SCADA package or an HMI can read its tags, and Sparkplug B publishing with store and forward, so readings queue on disk through an uplink outage, up to a limit you size to your rate. It keeps history in TimescaleDB, PostgreSQL or a SQLite file.
- HotLoop IoT is the automation base, small enough for a Raspberry Pi: entities, automations, scripts, the logbook, notifications, MCP, ISA-18.2 alarms and backups, with history in PostgreSQL or a SQLite file.
- HotLoop Edge Relay polls devices and forwards every reading to a Gateway over Sparkplug B. It has no database and no web interface.
- HotLoop Flow is a visual flow engine for the
plant floor, written in Go, that also runs your Node-RED
flows.json. - HotLoop Cascade is workflow automation where every step is checkpointed, so a job finishes even if an API is down.
- HotLoop for CODESYS runs HotLoop beside a CODESYS runtime, with the screens and alarms for the PLC.
HotLoop Transmitter is the eighth. It is a CODESYS library, not an App Store app, that publishes PLC values as OPC UA PubSub over UDP. See Transmitter on hotloop.io and its documentation.
The first four are built on HotLoop's protocol drivers, so a driver fix reaches every one of them. Flow and Cascade are their own products on their own releases.
Running on EmberNet
- The Gateway deploys as a single instance per node, with its database alongside it in the same release.
- Size the node for the historian you plan to keep.
- Since 4.17.0, device passwords are encrypted at rest with a key generated for your install and kept across upgrades. That key is part of your data: back it up somewhere other than next to your backups, because restoring credentials needs it.
- Coming from 4.16.0 or 4.3.1, read HotLoop's upgrade guide before you upgrade. A plain upgrade from 4.3.1 fails outright.
Licensing
HotLoop Gateway is under the EmberNet Source License 1.0, like every HotLoop product. You can copy, modify, and redistribute it, and any non-production use is allowed. Production use is allowed three ways: at home or in a lab, by schools, nonprofits, and government bodies for their own mission, and anything run through EmberNet, business use included, where signing up is free. A systems integrator can run it under its own EmberNet account for a customer and charge for its services, never for the software. Each version becomes available under AGPL-3.0-or-later four years after it's first made public. See the license and Using HotLoop in a business. There's no license key, because which product you run is just which image you pulled. Support, SLAs, and rollouts come from Fireball Industries, HotLoop's Official Systems Integrators.
Learn more
- HotLoop Gateway documentation
- Install the Gateway
- HotLoop Gateway on hotloop.io
- Release notes and the license